Applying Sound Research Methodology to Ensure Accuracy and Validity of Infusion Pump Alarm Data

Abstract: This article explains the complexities of collating infusion pump alarm data across multiple hospital datasets and describes a research‐based process to maximize the accuracy and validity of the data. Finding no comparable process in the literature, the researchers created and tested a validation methodology to ensure accurate and valid reporting of infusion alarm data metrics and benchmarks.

Reference: Schuster C, Vitoux R. Applying sound research methodology to ensure accuracy and validity of infusion pump alarm data. Biomed Instrum Technol, 2018; 52(3): 192‐198.

Learn More >

Perceptions of Infusion Pump Alarms: Insights Gained from Critical Care Nurses

Abstract: The authors developed and used an infusion pump‐specific alarm survey to measure nurse perceptions of pump alarms and compared the results with those reported by studies that measured clinical alarms in general. The findings indicated that nurses overwhelmingly agree that infusion pump nuisance alarms occur frequently and disrupt patient care, but nurses’ perceptions of pump alarms are different from those previously reported for clinical alarms in general.

Reference: Vitoux, R, Schuster C, Glover G. Perceptions of infusion pump alarms: Insights gained from critical care nurses. J Infus Nurs, 2018; 41(5): 309‐318.

Learn More > 

Achieving Outcomes with Innovative Smart Pump Technology: Partnership, Planning and Quality Improvement

Abstract: A 5‐time designated Magnet academic medical center partnered with B.Braun Medical to successfully integrate 1327 smart pumps across 45 departments in an aggressive 3‐month timeline. Quality improvement outcomes included 100% drug library compliance across all 6 intensive care units, a decrease in pump alert rate from 4.18% to 0.79% and a decrease in pump programming correction rate from 0.36% to 0.06%.

Reference: Lehr J, Vitoux, RR, Zavotsky KE, Pontieri‐Lewis V, Colineri L. Achieving outcomes with innovative smart pump technology: Partnership, planning and quality improvement. J Nsg Care Qual, 2018; April 9 [Epub].

Learn More > 

Types and Frequency of Infusion Pump Alarms: Protocol for a Retrospective Data Analysis

Abstract: Since research related to the types and frequencies of actionable infusion pump alarms remains largely unexplored, this study protocol is designed to provide new insights regarding the types and frequency of infusion pump alarms. Infusion pump alarm data collected and analyzed in this study will be used to help establish a baseline of infusion pump alarm types and relative frequencies.

Reference: Glover KR, Vitoux RR, Schuster C, Curtin CR. Types and frequency of infusion pump alarms: Protocol for a retrospective data analysis. JMIR Res Protoc, 2018; 7(6):e10446

Learn More > 

Collaboration Fuels Success of Infusion Management Interoperability Initiative

Abstract: Improved patient safety and documentation accuracy were achieved at this medical center through smart pump‐EMR integration and process improvement tools, including B.Braun’s DoseTrac real‐time dashboard, reporting and analysis service. Outcomes included > 90% medication scanning compliance, 65% improvement in pump association with the patient, only 1% dose correction incidence and a 50% decrease in infusion errors.

Reference: Razanno L, Box A, Corrick K, McDowell J, Vitoux R. Collaboration fuels success of infusion management interoperability initiative. Biomed Instrum Technol, 2018; 52(1): 38‐43.

Learn More > 

The Crucial Link in Successful Smart Pump Adoption: The Critical Care Nurse

Abstract: Successful adoption of smart pump and related technologies requires ongoing communication, collaboration and partnership to achieve sustainable impact on patient safety outcomes. The authors discuss the phases of smart pump adoption and the role of the critical care nurse in helping to achieve patient safety outcomes and zero IV pump‐related errors.

Reference: Kavanagh T, Tse E, Vitoux R. The crucial link in successful smart pump adoption: The critical care nurse. Can J Crit Care Nurs, 2017; 28(4): 29‐34.

Learn More > 

Hardening Infusion Pump Communication Software for Medical Device Cyber Security

Abstract: A proactive approach is necessary to identify ways that device manufacturers can improve cybersecurity to prevent access to devices and system software. The approach described in this article can be used to identify, neutralize, and lock out unauthorized access, thereby permitting only approved access. This approach includes the following:

  • Hardening to conduct a device cybersecurity risk assessment
  • Researching and monitoring the NIST common vulnerabilities and exposures list to learn about cyber security issues and threats in the OS and applications
  • Configuring system software to manage access for software processes
  • Disabling unused software services and communication ports

Reference: Smigielski, R. Hardening infusion pump communication software for medical device cybersecurity. Horizons, 2017; 51(s6): 46‐51.

Learn More >

Prevalence and Characteristics of Infusion Pump Alarms in the ICU: A Retrospective Data Analysis

Abstract: Infusion pump alarm data was collected from 9151 pumps used in 55 ICUs across the U.S. Of 291,091 infusion deliveries, there were an average of 2.3 alarms per delivery, an average alarm duration of 1 min. 25 sec., and pumps were in an alarm state only 0.3% of the total infusion time. Alarm frequency was also quantified by alarm type, type of infusion and day of week. 

Reference: Research poster presentation at the AACN NTI, Houston, TX, May 2017.

Learn More >

Integration of Infusion Pumps with EHR Reduces IV Medication Errors

Abstract:  Great River Health Systems implemented B.Braun smart pumps with DoseTrac real-time dashboards, reporting and analytic services and integrated the system with their EHR to help improve patient safety, quality, and cost. According to GRHS, outcomes include reducing alerts from 15% to 1%, improving auto-programming compliance, and reducing medication errors with an associated savings of $70,000.

Learn More > 

Passion for Safety Underpins Healthcare System's Infusion Pump Upgrade

Abstract:  Since 2011, Western Maryland Regional Medical Center has shown continued success in improving patient safety, alarm systems and clinical practice, including sustained drug library compliance rates of 98-100% over 5 years. The Medical Center implemented B.Braun smart pumps with patient ID scan and EMR integration capacity, along with DoseTrac real-time monitoring of infusions from nurses' stations and pharmacy, weekly audits, and analytic services to optimize compliance and improve practice.

Learn More >

Establishing Benchmarks and Identifying Opportunities to Reduce Alert Fatigue Associated with Smart Infusion Pumps

Abstract:  Alert analysis of over 4 million infusion therapies across 50 U.S. hospitals found only 1% of therapies were associated with dosing alerts, with only a 0.1% correction frequency. This low correction rate indicates a low incidence of programming error associated with single channel pumps with non-numeric keypads. Alert analysis with drug library adjustments and education has helped hospitals achieve up to 99% reduction in alerts, up to 100% drug library use, and a significant reduction in infusion related medication errors.

Reference: Research poster presentation at the ASHP Midyear Meeting, Dec 2015.

Learn More >

Are You Connected? Get Ready to Reduce Alarms, Avoid Alarm Fatigue and Improve Patient Safety

Abstract: Mount Sinai Beth Israel continues to document success across a four hospital system reducing alerts, programming errors, and maintaining 100% drug library compliance by monitoring alerts and drug library compliance with B. Braun’s DoseTrac real time monitoring, reporting and analytic services. Overall alerts continued to decrease as total infusions increased, from 2.74% of infusions to only 0.75% of infusions in 9 months in 2014 with a very low programming error rate of 0.05%. Alerts on key medications decreased 22- 97% by the end of 2014.

Learn More >

Exemplary Implementation and Utilization of Smart Pump Technology

Abstract: Robert Wood Johnson University Hospital utilized Lean principles and B. Braun’s DoseTrac real time monitoring, reporting and analytic services to achieve 100% use of the drug library in ICU and very low programming error rate of 0.19% as well as reduce dosing alerts from 4.18% to 1.16%.

Learn More >

Improve Infusion Safety and Reduce Alarm Fatigue in the ICU

Abstract: Over a 3 year study period, Mount Sinai Beth Israel health system steadily reduced their smart pump drug library alerts using B. Braun’s DoseTrac Infusion Management Software and Analytic Service. Alerts were reduced 70% overall in 2013, and an additional 58% in 2014 across the 4 hospitals.

Reference: Sullivan, C. Improve infusion safety and reduce alarm fatigue in the ICU. Presentation at the American Association of Critical-Care Nurse National Teaching Institute, Denver, CO.

Learn More >

Smart Pump Wireless Technology: An IQ Boost for the Pump

Abstract: Mount Sinai Beth Israel Hospital used B.Braun smart pumps with DoseTrac real time monitoring and analytics to improve patient safety, reduce alerts by 45-88%, improve practice and achieve 100% drug library utilization in ICU.

Reference: Palillo, E., Sullivan, C., Geller, CM. Use of smart pumps in a cardiac surgery intensive care unit improves patient safety and reduces alerts. Poster Presentation at the FACTS-Care Cardiovascular-Thoracic Critical Care Annual Conference, Washington, D.C.,  2013.

Learn More >

Use of "Smart Pumps" In a Cardiac Surgery Intensive Care Unit Improves Patient Safety and Reduces Alerts

Abstract: Beth Israel Hospital:  Wireless integration of B.Braun smart pumps with DoseTrac  provided real time monitoring and retrospective reporting on dosing trends and practices in a CSICU. Six month data analysis identified  interventions to reduce alerts and resulted in 45-88% alert reduction across 5 targeted infusions.

Reference: Palillo, E., Sullivan, C., Geller, CM. Use of smart pumps in a cardiac surgery intensive care unit improves patient safety and reduces alerts. Poster Presentation at the FACTS-Care Cardiovascular-Thoracic Critical Care Annual Conference, Washington, D.C.,  2013.

Learn More >

Forget Smart Phones- What You Need Are Smart Pumps

Abstract: Beth Israel Hospital:  Major NYC medical center selected B.Braun smart pumps for safety features including DoseTrac real time monitoring and wireless reporting software, ease of use and single channel device.  Achieved 100% drug library utilization in Critical Care and significant reduction in alerts through dosing limit modifications, education and weekly DoseTrac reports.

Reference: Sullivan, C. Forget smart phones – What you need are smart pumps! Presentation at the American Association of Critical-Care Nurse National Teaching Institute, Boston, MA, 2013.

Learn More >

Smart Pumps: Achieving 100% Drug Library Compliance and Averting Medication Errors

Abstract: B. Braun smart pump technology integration with DoseTrac real time monitoring and retrospective reports resulted in improved medication safety, faster recognition and response to alarms and preventing patient harm. Outcomes included  100% compliance across 4 drug library metrics and 7 ADEs averted in first 3 months of implementation. (presentation)

Reference: Ruhl, C., & Grogg, C. Smart pumps:  Achieving 100% drug library compliance and averting medication errors. Presentation at the American Association of Critical-Care Nurse National Teaching Institute, Boston, MA, 2013.

Learn More >

Improving Medication Infusion Safety Through Technology and Practice

Abstract: In just 3 years post implementation, Lutheran Medical Center achieved 0 infusion-related medication events using B.Braun smart pumps and DoseTrac Data Analysis Service. Other outcomes included 100% compliance with dose mode (drug library), 100% weight-based ordering practice, 0 alerts with heparin or insulin and low incidence of programming errors (0.5%).

Reference: Raso, R., Velletri, J., & DiCrescento, S.  Improving medication infusion safety through technology and practice. Presentation at the American Organization of Nurse Executives 42nd Annual Conference, San Antonio, TX, 2009.

Learn More >

B. Braun's Outlook 400ES

Abstract: University of Illinois Medical Center used B. Braun DoseTrac alert reports to identify potential medication errors and make changes to drug limits, achieving near 100% compliance with one of the drug libraries in the ICU areas.

Reference: Garofalo, J. Product spotlight: B.Braun’s Outlook 400ES. Pharmacy Purchasing & Products, 2009;6(11).

Learn More >

Making the Most of Data for Patient Safety

Abstract: Within the first year of implementing B.Braun smart pumps and DoseTrac Data Analysis Service, Lutheran Medical Center experienced a very low incidence of manual programming errors and achieved a 57% decrease in infusion related medication events.

Reference: Raso, R., Velletri, J., & DiCrescento, S. Making the most of data for patient safety. Patient Safety & Quality Healthcare Magazine, May/June 2007; 32-35.

Learn More >