Emergency Department Single-Shot Nerve Block Tray

Ready for emergency care.

The US market leader in regional anesthesia.1

Improving outcomes in the emergency department with regional anesthesia.

  • Safe and effective alternative to opioid therapies2
  • Improves patient satisfaction and reduces pain scores2
  • Helps reduce the transition of acute to chronic pain3
  • Decreases length of stay and lowers in-hospital costs4

Visibility without compromise

Stimuplex® Ultra 360® and Ultraplex 360® Needles feature B. Braun’s echogenic 360° X-pattern. The ‘X’ is a unique shape which, when combined with a clear coating, is intended to reflect more ultrasound waves back to the probe than previous designs.5 These needles are designed to provide visibility without compromising puncture characteristics, featuring the same 30° bevel found on other market-leading1 Stimuplex Needles.

Design benefits:

  • Better Echogenicity — X-pattern and clear coating result in better ultrasound visualization and tip identification5
  • 360° Visibility — 360° markings designed for ultrasound visibility from all sides
  • 30° Back-Cut Bevel — Designed for consistent puncture and feel
  • Short-short-long pattern — Helps to enable distinction between the needle tip and the upper needle shaft

Preferred 91% Over Competition6

Components:

  • 20 Ga. x 4 in. Ultraplex® 360 Needle
  • Sodium Chloride (0.9%) 10 mL – Qty. 2
  • 3 mL Applicator Chloraprep Hi-Lite Orange
  • 4-way High Flow Stopcock
  • Transducer Cover and Gel (30 cm)
  • Drape
  • 10 mL Luer Lock Plastic Syringe
  • 30 mL Luer lock Plastic Syringe
  • Adhesive Bandage
  • Filter Needle, 5 micron – 19 Ga. × 1½ in.
  • Needle Block Foam and Holder – Round
  • Gauze
  • Skin Marker

     

1. IMS Data Q4 2020

2. Goldsmith, A., Driver, L., Duggan, N. M., Riscinti, M., Martin, D., Heffler, M., Shokoohi, H., Dreyfuss, A., Sell, J., Brown, C., Fung, C., Perice, L., Bennett, D., Truong, N., Jafry, S. Z., Macias, M., Brown, J., & Nagdev, A. (2024). Complication Rates After Ultrasonography-Guided Nerve Blocks Performed in the Emergency Department. JAMA Network Open, 7(11), e2444742. https://doi.org/10.1001/ jamanetworkopen.2024.44742

3. Malik, A., Thom, S., Haber, B., Sarani, N., Ottenhoff, J., Jackson, B., Rance, L., & Ehrman, R. (2022). Regional Anesthesia in the Emergency Department: an Overview of Common Nerve Block Techniques and Recent Literature. Current Emergency and Hospital Medicine Reports, 10(3), 54–66. https://doi.org/10.1007/s40138-022-00249-w

4. Cogan, C. J., & Kandemir, U. (2020). Role of peripheral nerve block in pain control for the management of acute traumatic orthopaedic injuries in the emergency department: Diagnosis-based treatment guidelines. Injury, 51(7), 1422–1425. https://doi.org/10.1016/j.injury.2020.04.016

5. Engineering Test Report NPAK-A8TP1B

6. Cooper D, van Geffen GJ, Bruaset I, et al. Regional block needles: a matter of feel and brightness. Poster presented at 35th Annual European Society of Regional Anaesthesia Congress September 7-10, 2016; Maastricht, Limburg, Netherlands.

 

Contact a Representative

Please take a minute to complete the request form or call 1-800-227-2862 to contact a B. Braun representative. Thank you.

more

Specifications

Product Identification
Product Code 570348
WSN Number 08021-5703-48
Reference Number 570348
Safety Data
Latex Information Not Made With Natural Rubber
Storage and Shipping
Total Shelf Life (Months) 024
Ordering Unit Case
Units per Case 10
Dimensions per Case 20.240 x 9.740 x 11.730 inches
Shipping Weight per Case 6.649 lb
Sterility
Sterile Yes